UltraGas 2 (125-500)

Please select the desired product type.

Nominal heat output at 80/60 °C, natural gas: 21 - 114 kW
Nominal heat output at 50/30 °C, natural gas: 25 - 126 kW
Operating pressure max.: 6 bar
Boiler efficiency (GCV) at 80/60 °C in full-load operation: 88.9 %
Boiler efficiency (GCV) at 30 % partial load (EN 15502): 98.1 %
Sound power level heating noise (EN 15036 part 1) (room air dependent): 64 dB(A)
Nominal heat output at 80/60 °C, natural gas: 33 - 139 kW
Nominal heat output at 50/30 °C, natural gas: 35 - 151 kW
Operating pressure max.: 6 bar
Boiler efficiency (GCV) at 80/60 °C in full-load operation: 88.1 %
Boiler efficiency (GCV) at 30 % partial load (EN 15502): 98.1 %
Sound power level heating noise (EN 15036 part 1) (room air dependent): 69 dB(A)
Nominal heat output at 80/60 °C, natural gas: 35 - 177 kW
Nominal heat output at 50/30 °C, natural gas: 38 - 191 kW
Operating pressure max.: 6 bar
Boiler efficiency (GCV) at 80/60 °C in full-load operation: 88.7 %
Boiler efficiency (GCV) at 30 % partial load (EN 15502): 98.2 %
Sound power level heating noise (EN 15036 part 1) (room air dependent): 63 dB(A)
Nominal heat output at 80/60 °C, natural gas: 47 - 218 kW
Nominal heat output at 50/30 °C, natural gas: 51 - 233 kW
Operating pressure max.: 6 bar
Boiler efficiency (GCV) at 80/60 °C in full-load operation: 88.5 %
Boiler efficiency (GCV) at 30 % partial load (EN 15502): 97.8 %
Sound power level heating noise (EN 15036 part 1) (room air dependent): 66 dB(A)
Nominal heat output at 80/60 °C, natural gas: 54 - 274 kW
Nominal heat output at 50/30 °C, natural gas: 58 - 299 kW
Operating pressure max.: 6 bar
Boiler efficiency (GCV) at 80/60 °C in full-load operation: 88.3 %
Boiler efficiency (GCV) at 30 % partial load (EN 15502): 98.4 %
Sound power level heating noise (EN 15036 part 1) (room air dependent): 73 dB(A)
Nominal heat output at 80/60 °C, natural gas: 67 - 315 kW
Nominal heat output at 50/30 °C, natural gas: 70 - 352 kW
Operating pressure max.: 6 bar
Boiler efficiency (GCV) at 80/60 °C in full-load operation: 88.5 %
Boiler efficiency (GCV) at 30 % partial load (EN 15502): 98.1 %
Sound power level heating noise (EN 15036 part 1) (room air dependent): 70 dB(A)
Nominal heat output at 80/60 °C, natural gas: 62 - 362 kW
Nominal heat output at 50/30 °C, natural gas: 69 - 399 kW
Operating pressure max.: 6 bar
Boiler efficiency (GCV) at 80/60 °C in full-load operation: 88.5 %
Boiler efficiency (GCV) at 30 % partial load (EN 15502): 98.2 %
Sound power level heating noise (EN 15036 part 1) (room air dependent): 73 dB(A)
Nominal heat output at 80/60 °C, natural gas: 73 - 415 kW
Nominal heat output at 50/30 °C, natural gas: 77 - 451 kW
Operating pressure max.: 6 bar
Boiler efficiency (GCV) at 80/60 °C in full-load operation: 88.5 %
Boiler efficiency (GCV) at 30 % partial load (EN 15502): 98.1 %
Sound power level heating noise (EN 15036 part 1) (room air dependent): 74 dB(A)
Nominal heat output at 80/60 °C, natural gas: 71 - 449 kW
Nominal heat output at 50/30 °C, natural gas: 77 - 491 kW
Operating pressure max.: 6 bar
Boiler efficiency (GCV) at 80/60 °C in full-load operation: 88.5 %
Boiler efficiency (GCV) at 30 % partial load (EN 15502): 98.2 %
Sound power level heating noise (EN 15036 part 1) (room air dependent): 78 dB(A)